100417
SDAINLM16(24VDC)
Star-delta contactor combination, 380 V 400 V: 7.5 kW, 24 V DC, DC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Accessories: Star-delta combinations SDAINL, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 16 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 4 kW, 380 V 400 V: P= 7.5 kW, 500 V: P= 7.5 kW, 660 V 690 V: P= 7.5 kW, Max. changeover time: 20 s, Actuating voltage: 24 V DC, Voltage AC/DC: DC operation, Individual components of the combination Mains contactor Q11: DILM9-10 , + DILA-XHI20, Delta contactor Q15: DILM9-01, + DILA-XHI20 Part no., Star contactor Q13: DILM7-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015081003945
1.19000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
278408
SDAINLM55(110V50HZ,120V60HZ)
Star-delta contactor combination, 380 V 400 V: 30 kW, 110 V 50 Hz, 120 V 60 Hz, AC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 55 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 15 kW, 380 V 400 V: P= 30 kW, 500 V: P= 37 kW, 660 V 690 V: P= 30 kW, Max. changeover time: 20 s, Actuating voltage: 110 V 50 Hz, 120 V 60 Hz, Voltage AC/DC: AC operation, Individual components of the combination Mains contactor Q11: DILM32-10, + DILA-XHI20 , Delta contactor Q15: DILM32-01, + DILA-XHI20 Part no., Star contactor Q13: DILM25-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015082784089
1.61000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
278336
SDAINLM22(230V50HZ,240V60HZ)
Star-delta contactor combination, 380 V 400 V: 11 kW, 230 V 50 Hz, 240 V 60 Hz, AC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Accessories: Star-delta combinations SDAINL, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 22 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 5.5 kW, 380 V 400 V: P= 11 kW, 500 V: P= 11 kW, 660 V 690 V: P= 11 kW, Max. changeover time: 20 s, Actuating voltage: 230 V 50 Hz, 240 V 60 Hz, Voltage AC/DC: AC operation , Individual components of the combination Mains contactor Q11: DILM12-10, + DILA-XHI20, Delta contactor Q15: DILM12-01, + DILA-XHI20 Part no., Star contactor Q13: DILM7-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015082783365
1.03000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
100418
SDAINLM22(24VDC)
Star-delta contactor combination, 380 V 400 V: 11 kW, 24 V DC, DC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Accessories: Star-delta combinations SDAINL, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 22 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 5.5 kW, 380 V 400 V: P= 11 kW, 500 V: P= 11 kW, 660 V 690 V: P= 11 kW, Max. changeover time: 20 s, Actuating voltage: 24 V DC, Voltage AC/DC: DC operation, Individual components of the combination Mains contactor Q11: DILM12-10 , + DILA-XHI20, Delta contactor Q15: DILM12-01, + DILA-XHI20 Part no., Star contactor Q13: DILM7-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015081003952
1.19000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
100421
SDAINLM55(RDC24)
Star-delta contactor combination, 380 V 400 V: 30 kW, 24 V DC, DC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Accessories: Star-delta combinations SDAINL, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 55 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 15 kW, 380 V 400 V: P= 30 kW, 500 V: P= 37 kW, 660 V 690 V: P= 30 kW, Max. changeover time: 20 s, Actuating voltage: 24 V DC, Voltage AC/DC: DC operation, Individual components of the combination Mains contactor Q11: DILM32-10 , + DILA-XHI20, Delta contactor Q15: DILM32-01, + DILA-XHI20 Part no., Star contactor Q13: DILM25-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015081003983
1.93000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
278358
SDAINLM30(110V50HZ,120V60HZ)
Star-delta contactor combination, 380 V 400 V: 15 kW, 110 V 50 Hz, 120 V 60 Hz, AC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 30 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 7.5 kW, 380 V 400 V: P= 15 kW, 500 V: P= 18.5 kW, 660 V 690 V: P= 18.5 kW, Max. changeover time: 20 s, Actuating voltage: 110 V 50 Hz, 120 V 60 Hz, Voltage AC/DC: AC operation, Individual components of the combination Mains contactor Q11: DILM17-10, + DILA-XHI20 , Delta contactor Q15: DILM17-01, + DILA-XHI20 Part no., Star contactor Q13: DILM17-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015082783587
1.61000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
100420
SDAINLM45(RDC24)
Star-delta contactor combination, 380 V 400 V: 22 kW, 24 V DC, DC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Accessories: Star-delta combinations SDAINL, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 45 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 11 kW, 380 V 400 V: P= 22 kW, 500 V: P= 30 kW, 660 V 690 V: P= 22 kW, Max. changeover time: 20 s, Actuating voltage: 24 V DC, Voltage AC/DC: DC operation, Individual components of the combination Mains contactor Q11: DILM25-10 , + DILA-XHI20, Delta contactor Q15: DILM25-01, + DILA-XHI20 Part no., Star contactor Q13: DILM17-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015081003976
1.93000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
278386
SDAINLM45(230V50HZ,240V60HZ)
Star-delta contactor combination, 380 V 400 V: 22 kW, 230 V 50 Hz, 240 V 60 Hz, AC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Accessories: Star-delta combinations SDAINL, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 45 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 11 kW, 380 V 400 V: P= 22 kW, 500 V: P= 30 kW, 660 V 690 V: P= 22 kW, Max. changeover time: 20 s, Actuating voltage: 230 V 50 Hz, 240 V 60 Hz, Voltage AC/DC: AC operation , Individual components of the combination Mains contactor Q11: DILM25-10, + DILA-XHI20, Delta contactor Q15: DILM25-01, + DILA-XHI20 Part no., Star contactor Q13: DILM17-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015082783860
1.61000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
278286
SDAINLM12(230V50HZ,240V60HZ)
Star-delta contactor combination, 380 V 400 V: 5.5 kW, 230 V 50 Hz, 240 V 60 Hz, AC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Accessories: Star-delta combinations SDAINL, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 12 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 3 kW, 380 V 400 V: P= 5.5 kW, 500 V: P= 5.5 kW, 660 V 690 V: P= 5.5 kW, Max. changeover time: 20 s, Actuating voltage: 230 V 50 Hz, 240 V 60 Hz, Voltage AC/DC: AC operation , Individual components of the combination Mains contactor Q11: DILM7-10, + DILA-XHI20, Delta contactor Q15: DILM7-01, + DILA-XHI20 Part no., Star contactor Q13: DILM7-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015082782863
1.03000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
101381
SDAINLM16(400V50HZ)
Star-delta contactor combination, 380 V 400 V: 7.5 kW, 400 V 50 Hz, AC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Accessories: Star-delta combinations SDAINL, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 16 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 4 kW, 380 V 400 V: P= 7.5 kW, 500 V: P= 7.5 kW, 660 V 690 V: P= 7.5 kW, Max. changeover time: 20 s, Actuating voltage: 400 V 50 Hz, Voltage AC/DC: AC operation, Individual components of the combination Mains contactor Q11: DILM9-10 , + DILA-XHI20, Delta contactor Q15: DILM9-01, + DILA-XHI20 Part no., Star contactor Q13: DILM7-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015081011247
1.03000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
101383
SDAINLM30(400V50HZ)
Star-delta contactor combination, 380 V 400 V: 15 kW, 400 V 50 Hz, AC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Accessories: Star-delta combinations SDAINL, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 30 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 7.5 kW, 380 V 400 V: P= 15 kW, 500 V: P= 18.5 kW, 660 V 690 V: P= 18.5 kW, Max. changeover time: 20 s, Actuating voltage: 400 V 50 Hz, Voltage AC/DC: AC operation, Individual components of the combination Mains contactor Q11: DILM17-10 , + DILA-XHI20, Delta contactor Q15: DILM17-01, + DILA-XHI20 Part no., Star contactor Q13: DILM17-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015081011261
1.61000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
100419
SDAINLM30(RDC24)
Star-delta contactor combination, 380 V 400 V: 15 kW, 24 V DC, DC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Accessories: Star-delta combinations SDAINL, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 30 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 7.5 kW, 380 V 400 V: P= 15 kW, 500 V: P= 18.5 kW, 660 V 690 V: P= 18.5 kW, Max. changeover time: 20 s, Actuating voltage: 24 V DC, Voltage AC/DC: DC operation, Individual components of the combination Mains contactor Q11: DILM17-10 , + DILA-XHI20, Delta contactor Q15: DILM17-01, + DILA-XHI20 Part no., Star contactor Q13: DILM17-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015081003969
1.93000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
278311
SDAINLM16(230V50HZ,240V60HZ)
Star-delta contactor combination, 380 V 400 V: 7.5 kW, 230 V 50 Hz, 240 V 60 Hz, AC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Accessories: Star-delta combinations SDAINL, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 16 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 4 kW, 380 V 400 V: P= 7.5 kW, 500 V: P= 7.5 kW, 660 V 690 V: P= 7.5 kW, Max. changeover time: 20 s, Actuating voltage: 230 V 50 Hz, 240 V 60 Hz, Voltage AC/DC: AC operation , Individual components of the combination Mains contactor Q11: DILM9-10, + DILA-XHI20, Delta contactor Q15: DILM9-01, + DILA-XHI20 Part no., Star contactor Q13: DILM7-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015082783112
1.03000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
101382
SDAINLM22(400V50HZ)
Star-delta contactor combination, 380 V 400 V: 11 kW, 400 V 50 Hz, AC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Accessories: Star-delta combinations SDAINL, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 22 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 5.5 kW, 380 V 400 V: P= 11 kW, 500 V: P= 11 kW, 660 V 690 V: P= 11 kW, Max. changeover time: 20 s, Actuating voltage: 400 V 50 Hz, Voltage AC/DC: AC operation, Individual components of the combination Mains contactor Q11: DILM12-10 , + DILA-XHI20, Delta contactor Q15: DILM12-01, + DILA-XHI20 Part no., Star contactor Q13: DILM7-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015081011254
1.03000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
101384
SDAINLM45(400V50HZ)
Star-delta contactor combination, 380 V 400 V: 22 kW, 400 V 50 Hz, AC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Accessories: Star-delta combinations SDAINL, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 45 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 11 kW, 380 V 400 V: P= 22 kW, 500 V: P= 30 kW, 660 V 690 V: P= 22 kW, Max. changeover time: 20 s, Actuating voltage: 400 V 50 Hz, Voltage AC/DC: AC operation, Individual components of the combination Mains contactor Q11: DILM25-10 , + DILA-XHI20, Delta contactor Q15: DILM25-01, + DILA-XHI20 Part no., Star contactor Q13: DILM17-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015081011278
1.61000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
278308
SDAINLM16(110V50HZ,120V60HZ)
Star-delta contactor combination, 380 V 400 V: 7.5 kW, 110 V 50 Hz, 120 V 60 Hz, AC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 16 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 4 kW, 380 V 400 V: P= 7.5 kW, 500 V: P= 7.5 kW, 660 V 690 V: P= 7.5 kW, Max. changeover time: 20 s, Actuating voltage: 110 V 50 Hz, 120 V 60 Hz, Voltage AC/DC: AC operation, Individual components of the combination Mains contactor Q11: DILM9-10, + DILA-XHI20 , Delta contactor Q15: DILM9-01, + DILA-XHI20 Part no., Star contactor Q13: DILM7-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015082783082
1.03000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
278333
SDAINLM22(110V50HZ,120V60HZ)
Star-delta contactor combination, 380 V 400 V: 11 kW, 110 V 50 Hz, 120 V 60 Hz, AC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 22 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 5.5 kW, 380 V 400 V: P= 11 kW, 500 V: P= 11 kW, 660 V 690 V: P= 11 kW, Max. changeover time: 20 s, Actuating voltage: 110 V 50 Hz, 120 V 60 Hz, Voltage AC/DC: AC operation, Individual components of the combination Mains contactor Q11: DILM12-10, + DILA-XHI20 , Delta contactor Q15: DILM12-01, + DILA-XHI20 Part no., Star contactor Q13: DILM7-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015082783334
1.03000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
101385
SDAINLM55(400V50HZ)
Star-delta contactor combination, 380 V 400 V: 30 kW, 400 V 50 Hz, AC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Accessories: Star-delta combinations SDAINL, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 55 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 15 kW, 380 V 400 V: P= 30 kW, 500 V: P= 37 kW, 660 V 690 V: P= 30 kW, Max. changeover time: 20 s, Actuating voltage: 400 V 50 Hz, Voltage AC/DC: AC operation, Individual components of the combination Mains contactor Q11: DILM32-10 , + DILA-XHI20, Delta contactor Q15: DILM32-01, + DILA-XHI20 Part no., Star contactor Q13: DILM25-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015081011285
1.61000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
101380
SDAINLM12(400V50HZ)
Star-delta contactor combination, 380 V 400 V: 5.5 kW, 400 V 50 Hz, AC operation
Star-delta contactor combination, Application: Star-delta motor starting for contactor combinations, Operating frequency: maximum 30 starts per hour, Accessories: Star-delta combinations SDAINL, Utilization category: NAC-3: Normal AC induction motors: starting, switch off during running, Rated operational current AC-3 380 V 400 V: Ie= 12 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 3 kW, 380 V 400 V: P= 5.5 kW, 500 V: P= 5.5 kW, 660 V 690 V: P= 5.5 kW, Max. changeover time: 20 s, Actuating voltage: 400 V 50 Hz, Voltage AC/DC: AC operation, Individual components of the combination Mains contactor Q11: DILM7-10 , + DILA-XHI20, Delta contactor Q15: DILM7-01, + DILA-XHI20 Part no., Star contactor Q13: DILM7-01, + DILA-XHI20 Part no., Timing relay K1: ETR4-51 Part no., Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging.
4015081011230
1.03000
Combination of contactor [AGZ572019]
Combination of contactors [EC000010]
Star-delta contactor
显示压缩表示形式 (24 Produkt)
标准代码Combination of contactors [EC000010] Basic version and enhancement
描述
公司Eaton's CAD
上次修改06.05.2025 19:11:56
单位
Combination of contactors [EC000010] Basic version and enhancement,,Eaton's CAD

CNS

CNSERPBASE Object Properties
Order Number101383